The laboratory mixer machine is suitable for the mixing of powders and granules with good material flowability and small physical property differences, as well as materials that do not require high mixing degree but require short mixing time. Because the material in the mixing container flows smoothly, the material will not be damaged. Therefore, the laboratory mixer is also suitable for the mixing of granular materials that are easily broken and easy to wear, or the mixing of finer powder, block, and materials containing a certain amount of water. It can be widely used in ceramsite, chemical industry, Environmental protection, refractory materials, brick products, wall panels and other industries.
The mixing of the materials in the laboratory mixer in the barrel is affected by the mechanical force to make the materials undergo complex relative motion, showing an accurate mixing state, promoting the diffusion range of the materials, increasing the mobility of the materials, and forming shearing of internal mixing fluctuations.
Features of Laboratory mixer machine:
A1: The pot body of the laboratory mixer: the parts in contact with the material are made of 304 stainless steel, with a thermal insulation layer, the inner wall is highly polished, and there is no material bonding.
A2: The lid of the laboratory mixer: it is made of stainless steel at the contact with the material. The inner surface is polished, with good self-cleaning and dust-proof sealing. With liquid material feeding hole and artificial feeding hole, it is convenient to connect.
A3: Laboratory mixer paddle: stainless steel 304 casting. The material has no dead zone during the mixing process, and eddy current can be obtained. Spacing is adjustable and worn paddles can be replaced in one piece. The surface has a wear-resistant coating for long life.
A4: Main shaft seal of laboratory mixer: metal labyrinth seal plus blowing air seal and oil seal, the material will not leak. The shaft sleeve is surface-hardened and has no wear. After replacing the oil seal, the sealing performance is the same as the new one.
Technical datas of Laboratory Mixer:
Type | Volume (L) | Effective
Volume (L) |
Mixing time
(min/batch) |
Rotate speed
(r/min) |
Motor
(Kw) |
Capacity
(kg/hour) |
SHR-5A | 5 | 3 | 6-8 | 1500 | 1.1 | 10 |
SHR-10A | 10 | 7 | 6-8 | 1500 | 3 | 20 |
SHR-25A | 25 | 20 | 6-8 | 1500 | 5.5 | 50 |
SHR-50A | 50 | 35 | 6-10 | 750/1500 | 7/11 | 100 |
SHR-100A | 100 | 75 | 6-10 | 650/1300 | 14/22 | 200 |
SHR-200A | 200 | 150 | 6-10 | 475/950 | 30/42 | 400 |
SHR-300A | 300 | 225 | 6-10 | 430/860 | 40/55 | 500 |
SHR-500A | 500 | 375 | 8-12 | 330/660 | 55/75 | 800 |
SHR-800A | 800 | 520 | 8-12 | 395/790 | 83/110 | 1400 |
SHR-1000A | 1000 | 650 | 8-14 | 330/660 | 90/132 | 1600 |
SHR-1300A | 1300 | 850 | 8-14 | 330/660 | 132/200 | 2100 |